MOCKUP · SAMPLE DATA← all screens
Evaluation due · 122 days

Sample data

Loaded monitoring results become the period averages and removal efficiencies below, computed once under the stated conventions — not typed in by hand, and not left for you to work out per pollutant.

Results loaded 184 sampling window 2025-Q1 to Q4
Pollutants with usable pairs 15/17 silver mostly ND · thallium has none
Non-detects 33 substituted at ½ detection limit
Worst mass-balance closure 61% mercury — two fifths unaccounted for
Results by pollutant
Period averages · 2025-Q1 to Q4 · mg/L
Pollutant Influent avg Effluent avg n Non-detects Removal Data quality
AntimonySb 0.0051 0.00306 12 2 40%
Arsenic (total)As 0.0051 0.00255 12 0 50%
AluminumAl 0.055 0.00825 12 0 85%
CadmiumCd 0.0051 0.001275 12 1 75%
Chromium (VI)Cr6 0.0017 0.00085 12 4 50%
Chromium (total)Cr 0.085 0.017 12 0 80%
CopperCu 0.1037 0.015555 12 0 85%
CyanideCN 0.0697 0.02788 12 3 60%
LeadPb 0.0833 0.01666 12 1 80%
MercuryHg 0.00051 0.000179 12 2 65%
MolybdenumMo 0.017 0.0119 8 0 30%
NickelNi 0.0357 0.019635 12 0 45%
SeleniumSe 0.0017 0.001105 12 5 35%
SilverAg 0.0085J 0.002125J 12 9 ref 75% 3 of 12 above detection
reference removal used
ThalliumTl no data ref 40% Insufficient data
human-health criterion + ref removal — provisional
TributyltinTBT 0.00042J 0.000126J 8 6 ref 70% 2 of 8 above detection
reference removal used
ZincZn 0.2975 0.0595 12 0 80%
Non-detects substituted at ½ the detection limit — applied to 33 results. J estimated — result between the detection and quantitation limits. Removal shown as ref where site data cannot support an observed rate.
Mass balance
Influent load vs effluent + biosolids

Influent load compared against effluent plus biosolids. Closure far from 100% means a sampling problem, not a treatment result.

Copper 97%
Zinc 94%
Lead 128%
Mercury 61%
Mercury closes at 61%. Roughly two fifths of the influent load is unaccounted for. Most often this is biosolids sampling timing rather than real loss — worth resolving before you rely on the mercury limit.
Conventions in force
Every derived value above assumes these — stated once, applied everywhere
AVG
Arithmetic mean of the period
Not a geometric mean. Metals loadings are additive.
ND
Substitute ½ detection limit
Applied to 33 results. State this in the submittal — reviewers check it.
MIN
8 pairs for an observed removal rate
Below that the study falls back to a reference rate automatically.
REF
Reference removals from EPA 2004 guidance
In use for silver 75%, tributyltin 70%, thallium 40% · EPA 833-R-04-002A
OUT
Outliers retained
Nothing is dropped silently. Exclusions require a written reason.